Hi,
We are using SUM tool to upgrade ECC 6.0 to EHP5 and we have finished
upto Check phase and now during summary we can see that it has finished
with warning:
++++++++++++++++++++++++++++++++++++++++++++
WARNING: Errors occurred during CHECK OF UPDATE TASK. For more
information, see the log file of the background job RSVBCHCK.PRD. The
following is the content of the summery error log file: The following
messages can be ignored in certain circumstances.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~CHECK OF UPDATE TASK ERRORS and RETURN CODE in RSVBCHCK.PRD
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~1 ETH010XRSVBCHCK: Check of open update requests
2EETG050 Update records still exist - Please process
A2EEMCEX 151 Entries for application "13" still exist in the extraction
queue ->
A2EEMCEX 141 Struct. appl. "02" cannot be changed due to setup table ->
Long text" ""MC02M_0CGRSETUP""300"
A2EEMCEX 141 Struct. appl. "02" cannot be changed due to setup table ->
Long text" ""MC02M_0HDRSETUP""300"
A2EEMCEX 141 Struct. appl. "02" cannot be changed due to setup table ->
Long text" ""MC02M_0ITMSETUP""300"
A2EEMCEX 141 Struct. appl. "02" cannot be changed due to setup table ->
Long text" ""MC02M_0SCLSETUP""300"
A2EEMCEX 141 Struct. appl. "02" cannot be changed due to setup table ->
Long text" ""MC02M_0SCNSETUP""300"
A2EEMCEX 141 Struct. appl. "02" cannot be changed due to setup table ->
Long text" ""MC02M_0SGRSETUP""300"
A2EEMCEX 141 Struct. appl. "04" cannot be changed due to setup table ->
Long text" ""MC04P_0ARBSETUP""300"
A2EEMCEX 141 Struct. appl. "04" cannot be changed due to setup table ->
Long text" ""MC04P_0COMSETUP""300"
A2EEMCEX 141 Struct. appl. "04" cannot be changed due to setup table ->
Long text" ""MC04P_0MATSETUP""300"
A2EEMCEX 141 Struct. appl. "17" cannot be changed due to setup table ->
Long text" ""MC17I00CSESETUP""300"
A2EEMCEX 141 Struct. appl. "17" cannot be changed due to setup table ->
Long text" ""MC17I00ITMSETUP""300"
A2EEMCEX 141 Struct. appl. "17" cannot be changed due to setup table ->
Long text" ""MC17I00NTFSETUP""300"
A2EEMCEX 141 Struct. appl. "17" cannot be changed due to setup table ->
Long text" ""MC17I00TSKSETUP""300"
A2EEMCEX 141 Struct. appl. "17" cannot be changed due to setup table ->
Long text" ""MC17I30HDRSETUP""300"
A2EEMCEX 141 Struct. appl. "17" cannot be changed due to setup table ->
Long text" ""MC17I30OPRSETUP""300"
++++++++++++++++++++++++++++++++++++++++++++
It says that we can proceed by ignoring this error, but need your opinion
before we proceed as we dont want to land into trouble by ignoring such
warning
Rableen Singh